IEC 62305 · Ed. 3.0:2024

IEC 62305, on one model of your building.

One building. Three studies. One document. Risk assessment (Part 2), LPS design (Part 3) and surge protection design (Part 4), all run against the same model — live in 2D and 3D.

Free to run every study. Pay once to unlock its documents — reissues included.

Change a dimension and the model redraws as you type. Save it, and every study whose numbers it moves says so — nothing silently describes a building that no longer exists.

Three studies of one building

3 studies live today. Describe the building once; each study reads what the others established. More electrical calculators to follow.

The protection level from Part 2 floors the Part 3 design; both feed the Part 4 schedule. Inherited values carry their source, a weaker choice is refused, a departure is printed as a departure — and an input changed after a study computed flags that study stale.

Lightning Risk

Live

IEC 62305-2 risk assessment → required protection level + PDF report.

🛡️

LPS Design

Live

IEC 62305-3 external LPS — air termination, down conductors, separation distance, earthing.

🔻

SPM Design

Live

IEC 62305-4 surge protection measures — LPZ layout, bonding network, and a manufacturer-neutral coordinated SPD specification.

The building is the model

Rectangle, L, T or U — the plan you enter is the plan every figure is drawn from, in the workspace and on the signed report alike.

The Voltbench workspace: an L-shaped building in 3D under two rolling spheres, with the design panel and the findings rail beside it.
The workspace: the design panel, the live model, and every study's findings on one screen. Dimensions to scale; illustrative positions say so on the figure itself.
A 2D site plan of an L-shaped building: the collection area follows the true outline, the air-termination mesh stops at the notch, and down conductors sit on the walls the building actually has.
Drawn from the true footprint, not a bounding box: the collection ring follows the L into the notch rather than squaring it off, and the down conductors sit on walls the building actually has. To scale, uniform on both axes.

Validated, and checkable

Built to IEC 62305 Ed. 3.0:2024 and reconciled figure by figure against Furse, DEHN, Schneider, Legrand and ITU-T worked examples — including the standard's own case studies. Every factor shows its clause citation and every input its coefficient. Where a published source disagrees with us, we publish that too.

Free to run. Pay for what you issue.

Run every study and read the on-screen result at no cost. One payment unlocks the full clause-referenced report — the working an engineer signs off on — as a printable document and PDF, with corrections to the same study reissued free. Buy it for one study, or once for every study of a building and the combined dossier.

Honest figures

Every drawing states what it claims: dimensions are measured and to scale; a position the design does not fix is labelled illustrative; a mark with no place to stand is omitted and the omission is named. A figure that cannot say that is a claim nobody made.

One document per building

Every study of a building composes into one clause-referenced dossier: each chapter exactly as issued, the shared basis stated once, and any disagreement surfaced rather than smoothed over.

Reports are frozen when issued — engine and standard edition stamped on every one — and reproduce exactly. When the building moves on, the dossier says which chapters no longer describe it, instead of letting an old number stand quietly beside a new drawing.

📄 Read a full sample dossier ↗
The dossier's shared-basis table: each value the studies share, which study established it, and the clause reference behind it.
The dossier's basis table: every shared value, the study that established it, and the clause behind it.

Describe your building once

Create a free account and run a full study today — or leave your email to hear when the all-access plan opens for sign-up and when new tools ship.